<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-22 09-55-14
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 57 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 68 kHz 12732 7,8856
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,1 dBr 5,27 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 68 kHz MIN: 11 kHz % above 76 kHz: 7,8856 Acquired: 2025/05/22 9.54.11 Total samples: 12732 Equivalent time: 0:10:36 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 6,1 dBr MIN: 4,1 dBr AVE: 5,27 dBr % above 12,2 dBr: 0,0 Last value: 6,0 dBr (2025/05/22 9.54.10) 09.40 09.42 09.44 09.46 09.48 09.50 09.52 09.54 0 2 4 6 Pm [dBr]